2014 high temperature air source heating

Industrial boilers

Product thermal capacity: 4-35 t/h

Working pressure: 1.0-2.5 MPA

Outlet temperature: 184-350 ℃

Available fuel: natural gas, coke oven gas, bio-gas,liquid propane gas, diesel, heavy oil, light oil, crude oil

Available industries: Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industries

  • Product introduction
  • Technical advantages
Introduction

2014 high temperature air source heating have a three-pass round coil structure. A conical coil is used for the effective protection of the furnace wall at the boiler end. This product is equipped with an advanced combustion device and is fully automated in operation. After the burner ignites the fuel, flame fills the round coil tubes and transfers heat by radiation through the tube wall (first pass). The high temperature flue gas gathers at the back door and then turns to the convection tubes section (second pass), where heat transfer takes place by convection. The flue gas gradually cools down here and flows to the front door, where it is reversed and goes into the third pass. After that, it enters into the chimney through the economizer and is released into the atmosphere.


2014 high temperature air source heating.This type of heater is delivered as a whole, and is installed on site, it only needs to connect thermal gas(oil) piping and electricity to start operation. The heater has four heating areas: furnace radiation heating area, the first convection tube bundle heating area, the second convection tube bundle heating area and economizer (waste heat boiler).

Digitized manufacture
  • The laying-off of steel tube adopts CNC 3D laser cutting machine.
  • The manufacture of round coil tube adopts CNC coil tube automatic production line. Once-forming and no need for plastic .
Full argon arc welding
  • The tube butt adopts argon arc welding technique and the seams will be done x ray real-time imaging, preventing unqualified seams from entering coil production line .
Easy operation
  • Heater is wholly assembled before delivery, it is easy for installation, debugging and operating.
  • Fully automatic operating, burning, liquid level of high level tank, outlet temperature and flow rate are adjusted automatically and self-protected.
  • The inlet and outlet with end flanges and flanged cover structure facilitate the installation and layout of tubeline in boiler house.
Less fuel consumption
  • Internal side adopts good insulation material, outside uses stainless steel plate, which can mostly reduce heat lost and make working environment better.
  • Multilayers closely spaced tube bundle and steel rod is used to seal and fix, completely eradicating short circuit of flue gas.
  • Before delivery, the residue moisture is removed completely, so the system draining period is reduced to 2 days from 12 days.
Safely operation
  • The inner coil tube has bigger flow rate, so it is more stable under high temperature operation.
  • Conical coil effectively protects the furnace wall at the end of heater and burner on the top.
2014 high temperature air source heating 2014 high temperature air source heating 2014 high temperature air source heating

Air Source Heat Pumps | Energy Saving Tru

2019-6-16 · Air source heat pumps (ASHPs) absorb heat from the outside air. This heat can then be used to heat radiators, underfloor heating systems, or warm air convectors and hot water in your home. Different from a ground source heat pump, an air source heat pump extracts heat from the outside air in the same way that a fridge extracts heat from its inside.

lexie@zozen.com > Get A Quote >

The PH+ guide to air source heat pumps

2019-6-15 · Air temperatures vary seasonally and moisture content fluctuates also, so an air source heat pump will always be at the mercy of the climate. The colder the air temperature, the harder the heat pump must work to lift the temperature up to what is required for heating.

lexie@zozen.com > Get A Quote >

A full air cooling and heating system based on min

According to the test data of automatic temperature and humidity monitoring system in Jisan mine, average air temperature at the entrance of the auxiliary pithead and the #18304 working face from August 18, 2012 to September 16, 2012 is shown in Fig. 1.It can be seen from the figure that when the ground temperature drops, temperature of each underground measuring point decreases.

lexie@zozen.com > Get A Quote >

A comparative analysis on experimental performanc

2018-6-16 · Shuai Deng Institute of Refrigeration & Cryogenics, Shanghai Jiao Tong University, Shanghai, China; Key Laboratory of Efficient Utilization of Low and Medium Grade Energy, Tianjin University, Ministry of Education of China, Tianjin, China Correspondence [email protected], Ruzhu Wang Institute of Refrigeration & Cryogenics, Shanghai Jiao Tong University, Shanghai, China

lexie@zozen.com > Get A Quote >

Performance evaluation of different heating terminal

Performance evaluation of different heating terminals used in air source heat pump system Évaluation de la performance des temperature difference fan-coil units for high efficient and comfort heating. CIESC J., 67 (S2) (2016), pp. 51-57 and air-conditioning system with air-source heat pump and low temperature difference fan coil indoor

lexie@zozen.com > Get A Quote >

How air source heat pumps work

How air source heat pumps work. Air source heat pumps absorb heat from the outside air. This heat can then be used to heat radiators, underfloor heating systems, or warm air convectors and hot water in your home. An air source heat pump extracts heat from the outside air in the same way that a fridge extracts heat from its inside.

lexie@zozen.com > Get A Quote >

Air to Water Heat Pump Systems | Economical heatin

Air Conditioning & Refrigeration. Daikin leverages its experience and technology to deliver air conditioning solutions that meet the demands of any setting. Hot water heated to 80℃ is available for domestic hot water and high temperature radiators. Both heating

lexie@zozen.com > Get A Quote >

Are Air Source Heat Pumps A Threat To Geotherma

2014-1-15 · Efficient air source heat pumps can now compete with geothermal heat pumps as a cost effective way to heat a home beyond the moderate climates where they have traditionally been used.

lexie@zozen.com > Get A Quote >

A study of the performances of low-temperatur

In Europe, high energy consumption in the building environment has raised the need for developing low-temperature heating systems both in new buildings and in retrofitting buildings. This paper

lexie@zozen.com > Get A Quote >

Air Source Heat Pumps Explained - Whic

Air source heat pumps explained. The ASHP absorbs heat from the outside air into a liquid at a low temperature, then the heat pump compressor increases the temperature of that heat. In the condenser, the hot liquid's heat is transferred to your heating and hot-water circuits. But if you're replacing a new heating system, an air source

lexie@zozen.com > Get A Quote >

Do Air Source Heat Pumps Work in Cold Climate

*For an ATW-65. As you can see, the heating capacity of this air source heat pump drops off as the temperatures decrease. Air source heat pumps are generally sized to produce enough heat for 80% – 90% of the annual heating load, and should be able to satisfy of your heating load when temperatures are above 0°C.

lexie@zozen.com > Get A Quote >